SmartFan® AC-VX

TECHNICAL DATA


AC-VX Motor Speed Control for Motors, Fans and Pumps

TESTING & TECHNICAL DATA

Fan/Motor Compatibility: The AC-VX is compatible with many PSC (Permanent Split Capacitor) and shaded pole motors. The AC-VX is not compatible with capacitor start motors. Confirm TRIAC controllability with the motor manufacturer before installation. Attempting to control a motor that is not compatible could cause excessive heating and could permanently damage the motor.

Voltage Loss:
For a typical fan, expect a voltage drop to the fan of about 4-10% at full voltage.

Changing Control Settings: The AC-VX will not recognize any changes in jumper settings made with power applied. Power must be turned OFF before changing any jumper settings.

Minimum Motor currents: Motors may not control properly if the total current draw is less than 0.5 Amp.

Maximum Motor currents: Some motors draw higher current at less than maximum voltage. Contact motor manufacturer for details.

TROUBLESHOOTING GUIDE

Output Always Measuring Full Voltage: (1) No motor connected. AC-VX requires a minimum 0.50 Amp load. (2) Wiring error bypassing AC-VX with “pigtailed” neutral wires. (3) Wrong or faulty sensor. (4) Incorrect jumper settings. (5) AC-VX damaged or defective.

Output always measuring zero volts: (1) No power to the AC-VX. (2) Wiring error or broken power wire(s). (3) Sensor/control signal is low or not connected. (4) Incorrect jumper settings. (5) AC-VX damaged or defective.

Output measuring wrong voltage: (1) wrong or faulty sensor. (2) Incorrect jumper settings. (3) AC-VX damaged or defective.

SPECIFICATIONS

  • Power Source: 115-230 VAC (+/- 15%)
  • Frequency 50/60 Hz (+/- 5%)
  • Output power rating at 40°C: 8 Amps
  • Minimum fan/motor load: 0.50 Amps
  • Input fuse: 15 Amp, Ceramic
  • Storage temperature: -40°C to 65°C
  • Operating temperature: -0°C to 55°C
  • Relative humidity: 5 to 95% non-condensing
  • Weight P/N 180V800: 10.7 oz. (303 grams)
  • Weight P/N 180V800E: 1.4 lb. (635 grams)

ADDITIONAL MANUAL PAGES

Use the links below for addtional manual pages or for a complete manual or click on the Operation/Installation Manual PDF link above.





Control Resources Home | News and Info | Technical Data | Catalog | Contact Us | Applications | About Control Resources | Site Map
Control Resources Incorporated 11 Beaver Brook Road Littleton MA, 01460 USA Tel: 978-486-4160 Fax: 978-486-4772 email: sales@controlres.com