CRI Catalog and Design Guide Section
 
View TachScan-9 Fan Speed Alarm Installation & Operation Manual in PDF


Click on drawing to view
large scale version
 
 TachScan-9 Fan Monitor Speed Alarm
SmartFan TachScan-9 is a digital fan monitor speed alarm for OEM control applications that monitors the tach pulses from up to nine DC or AC fans or blowers and provides OR’d pass/fail signals. TachScan-9 alarm accepts any supply voltage from 10 to 75 VDC, which is ideal for telecom and other cooling solution applications. TachScan-9 is compatible with any fan that provides open collector or voltage source tach pulses. Three trigger speeds are selectable by jumper.   If the speed of any air mover falls below the trigger speed, alarm signals are generated. Alarm signals can drive LEDs, logic, optical isolators or MOS Relays.

In addition to the standard line of SmartFan controls and alarms, Control Resources also provides custom control design and manufacturing services to provide you with the optimum cooling solution for your OEM control applications.

 
For Application, Design and
Custom Control Information See
:

 Features
  • Accepts any supply voltage from 6 to 75 VDC and distributes power
    to DC fans through the same  header used to sense tach pulses. It
    can also be used to power the DC tach circuits built into AC  fans.
  • Nine inputs monitor fans with any open collector or voltage sources tach pulses.
    The setting of a dipswitch allows fan headers to be disabled when fewer than
    nine fans are connected.
  • Provides individual outputs for each fan, which can drive logic, LEDs
    or remote optical isolators.
  • Provides OR’d outputs to drive two single LEDs or one bi-colored LED
  • Provides simultaneous NO and NC isolated outputs from a Dual-Pole
    MOS Relay which can sink up to 100 mA to drive heavy loads
  • Jumper sets trigger speed to 1,000, 2,000 or 4,000 PPM.
  • Compatible with any SmartFan speed controller
  • Small size of 5” X 1.5” permits mounting in small spaces within fan trays, etc.
  • Optional fan fusing is available.
 
 Specifications
Part Number Fan Type Supply Voltage Range Maximum Input Current Maximum Output Current to Any Fan
030M920 DC 6 to 60 VDC 8.0 Amps 4.0 Amps
042M920 DC 10 to 75 VDC 8.0 Amps 4.0 Amps
030M92010 AC 6 to 60 VDC 8.0 Amps Not Applicable
For Tach Circuit Only
H116 Hardware Pack

Note:  Maximum operating temperature is 65°C

To view installation and operation instructions:
View TachScan-9 Fan Speed Alarm Installation & Operation Manual in PDF



CRI Home | News & Info | Technical Data | Catalog | Contact Us | Applications | About Control Resources | Site Map |

Control Resources Incorporated
11 Beaver Brook Road
Littleton MA, 01460 USA
Tel: 978-486-4160
Fax: 978-486-4772
email: sales@controlres.com